CHANNEL RESERVE

Tool examples

See the tools at work.

Worked examples you can read without signing in. Each one is marked Example. The answers, quotes and prices shown are made up for illustration, and the drive and calculator answers are worked out by the site's own tools when this page is drawn. Nothing here comes from a member's inventory.

Find a part

One part number in. In stock, or not, out.

Type the part you're short on. Each search matches one exact part number: no wildcards and no partial matches. A part's second number, such as an order number, matches too.

The answer is in stock in the network, or not. No quantities, prices or member names.

A search displays another member's stock only in the manufacturer lines Channel Reserve has on file as your authorized lines, and it does not display stock held by a member whose states on file overlap yours. "Not in stock in the network" means no stock is displayed to you. These are filters on what the site displays, not rules about where or to whom anyone sells.

Find a partExample
Searched for 2904601
  • In stock in the networkPart 2904601Button: Request quotes

Request quotes sends the part and a quantity to the members holding it. They don't see who is asking.

Request quotes

Quotes come back without names.

A request states the part and the quantity, nothing else. It goes only to members holding the part, and they don't see who is asking.

Each holder decides whether to quote, at its own price and terms. A quote states the quantity the holder chooses to offer. You see the quotes as Quote 1, Quote 2 and so on. Accept one and, only then, you and that member learn who the other is. Every other holder is told only that the request is closed.

A request is open to quotes for 48 hours. Channel Reserve sets no formula, floor or cap and is not a party to the sale.

While the network is small, a member may be able to work out who holds a part or who is asking. With very few members, an answer cannot be fully anonymous.

Your requestExample
EXAMPLE-1000
A made-up part number. Quantity asked for: 4.
  • Quote 1Payment: Net 30 days. Freight: Collect, on the requester's carrier account. Ships in: 2 to 5 business days.Valid until Dec 1 $100.00 eachOffers 4 of the 4 asked forExample price Button: Accept
  • Quote 2Payment: Credit card. Freight: Prepaid and added to the invoice. Ships in: Same or next business day.Valid until Nov 29 $110.00 eachOffers 2 of the 4 asked forExample price Button: Accept
After you accept Quote 1 Quote 1 was sent by Example Supply Co. (a made-up name). You each now see the other's company, city and state, and the contact's name, title, email and phone.

Example prices and terms, made up for this page. Use what you learn through Channel Reserve only to complete this transaction.

Channel AI

No stock anywhere? Get the cross.

Ask about a part number and Channel AI says what the part is and, where it is confident, suggests the manufacturer's successor, a close variant, another maker's equivalent and the accessories that go with it.

Channel AI is given only the part number. No member data is sent to it.

One click then checks whether each suggestion is in stock in the network. Each check is a search of your own: logged, and counted toward your daily searches, the same as typing the number in. The display filters on a search apply to each check.

Suggestions are labeled Channel AI on every page. They can be wrong. Always confirm specs before quoting.

Channel AIExample answer from Channel AI
2866763
Phoenix Contact QUINT-PS/1AC/24DC/10. DIN-rail power supply, 24 V DC, 10 A.

Not in stock in the network

  • Replacement from the same manufacturer 2904601 Phoenix Contact QUINT4-PS/1AC/24DC/10
    • Same: 24 V DC
    • Same: 10 A
    • Same: DIN rail
    • Same: SFB boost

    Current-generation QUINT that replaces the 2866763. Same output rating; check the housing dimensions against the available panel space.

    In stock in the networkButton: Request quotes
  • Close variant from the same manufacturer 2903149 Phoenix Contact TRIO-PS-2G/1AC/24DC/10
    • Same: 24 V DC
    • Same: 10 A
    • Same: DIN rail
    • Different: SFB boost

    Same output in a simpler design. It doesn't have QUINT's SFB breaker-tripping boost, so confirm the application doesn't rely on it.

    Not in stock in the network

An answer is written the first time anyone asks about a part number, then kept for every member. Nothing about any member's stock is sent to Channel AI: the check is your own search. No product photos are shown.

Drive selector

Motor in. ABB type code out.

Motor horsepower, supply and duty in. The ABB drive type code rated for it out, read from ABB's published rating tables.

A drive is listed only when ABB's own table rates it for the motor at that supply and duty. Nothing is estimated, and each type code is one click from a search.

Confirm the type code, options and derating against ABB's current data sheet before you quote or order.

Drive selector: 460 V supply, normal duty, ACS580Example
MotorType codeRated currentFrame
5 hpACS580-01-07A6-47.6 AR1
10 hpACS580-01-014A-414 AR2
25 hpACS580-01-034A-434 AR3

The smallest ACS580 that ABB rates for each motor, worked out by the selector when this page was drawn.

Calculators

15 engineering calculators.

Each page lists what it assumes and where any table value comes from. The inputs travel in the page address, so a result can be bookmarked or sent to a coworker. Nothing is stored.

Cylinder force and air useExample

How hard does a 50 mm cylinder push at 6 bar?

Bore
50 mm
Supply pressure
6 bar
What the cylinder does
Moving a load (count on 50% of the force)

Count on 589 N (132.4 lbf) extending.

Extend force, theoretical1,178 N (264.8 lbf)Pressure times piston area.
Extend force to count on (50%)589 N (132.4 lbf)
DC voltage dropExample

What is left of 24 V after 30 m of 18 AWG at 2 A?

Supply voltage (V DC)
24
Current (A)
2
Cable length, one way
30 m
Wire size
18 AWG
Drop you can accept
5%

2.51 V lost, leaving 21.49 V at the device.

Resistance, out and back1.26 Ω18 AWG, solid copper at 20 °C.
Voltage drop2.51 V (10.5%)
Voltage at the device21.49 V
Longest run for 5% drop14.32 m (46.98 ft)One way, at this current and wire size.

That is more than the 5% you set. Use heavier wire, shorten the run, or feed the load from a supply closer to it.

A calculator is a starting point. Check the result against the manufacturer's data before you quote or build.

All 15 calculators

Pneumatics and vacuum

  • Cylinder force and air use
  • Vacuum cup sizing
  • Valve flow: Cv, Kv and Qn

Electrical and panels

  • DC power supply sizing
  • DC voltage drop
  • Enclosure cooling

Motors and motion

  • Motor full-load amps
  • Three-phase power
  • Gearmotor output
  • Conveyor drive
  • Moment of inertia
  • Move profile

Sensors and vision

  • Inductive sensor range
  • Camera field of view

Conversions

  • Unit converter

Part finders

Pick the specification. Get part numbers.

Pick the specification and get suggested part numbers for cordsets, photoelectric sensors, power supplies, circuit breakers, terminal blocks, contactors, interface relays, inductive proximity sensors, manual motor protectors, control transformers, enclosures, signal towers, pushbuttons, selector switches and pilot lights, AC drives, gear reducers, operator interfaces and temperature controllers. Every field is a fixed choice or a number, and only those choices are sent to the service behind Channel AI.

Channel AI can be wrong about part numbers and ratings, and it can suggest a part that does not exist. Check every suggestion against the manufacturer's data sheet before you quote or order.

Power supply finderExample answer from Channel AI

Mounting: DIN rail. Input: single-phase, 100 to 240 V AC. Output: 24 V DC, at least 10 A continuous. NEC Class 2 output: not required. Connection: any. DC OK signal contact: not required. Manufacturer: any well-known manufacturer.

  • 2904601Phoenix Contact. QUINT4-PS/1AC/24DC/10. 24 V DC, 10 A, single-phase input.
  • CP10.241PULS. 24 V DC, 10 A, single-phase input.
  • SDR-240-24Mean Well. 24 V DC, 10 A, single-phase input.

An example of the kind of answer a finder gives. It knows nothing about stock: Search the network says whether a part is in stock in the network.

Parts list check

Paste the quote. Get an answer for each line.

Paste up to 25 part numbers from a quote or a bill of materials and see, line by line, whether each is in stock in the network.

Each line is a search: it is logged and counts toward your daily search limit, the same as typing it in. The display filters on a search apply to each line.

Check a parts listExample
  • 2904601In stock in the network
  • ACS580-01-07A6-4In stock in the network
  • CP10.241Not in stock in the network

Each line gets the answer a search gives: in stock in the network, or not. No quantities, prices or member names.

Want list

Not in stock today? Wait for it.

Put the part on your want list. The list is checked once a day, and the site tells you when the part is in stock in the network.

The email says what a search would, and nothing else: no quantity, price or member name. The member holding the part is told nothing. The daily check applies the display filters on a search. A company can wait for up to 50 parts, each for 30 days.

Want list emailExample
  • CP10.241 is in stock in the network

The email names the part and says it is in stock in the network. No quantities, prices or member names.

Members only

The tools are part of membership.

Search, requests and every tool sit behind a member sign-in. Membership is by invitation.